Many
Manuals
search
Kategorie
Marki
Strona główna
Argoclima
Klimatyzatory typu split
AER522SCL3
Instrukcja Obsługi
Argoclima AER522SCL3 Instrukcja Obsługi Strona 20
Pobierz
Podziel się
Dzielenie się
Dodaj do moich podręczników
Drukuj
Strona
/
82
Spis treści
ROZWIĄZYWANIE PROBLEMÓW
BOOKMARKI
Oceniono
.
/ 5. Na podstawie
oceny klientów
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
2-3.
Other Component Specifications
1
6
Thermistor (Room sensor)
DTN-TKS142B
Resistance
k
Ω
25°C
5.0 ±
3%
Thermistor (Coil sensor)
DTN-TKS131B
Resistance
k
Ω
0°C
15.0 ± 2%
Transformer (TR)
ATR-J105
Rating
Primary
AC 230V, 50
/
60
Hz
Secondary
19V, 0.526A
Capacity
10VA
Coil resistance
Ω
(at 21°C)
Primary (WHT – WHT):
205 ± 10%
Secondary (BRN – BRN):
2.0 ± 10%
Thermal cut-off temp.
150°C
Indoor Unit
AWR518CL
AWR522CL
1
2
...
15
16
17
18
19
20
21
22
23
24
25
...
81
82
SPLIT SYSTEM AIR CONDITIONER
1
Important!
2
Please Read Before Starting
2
Table of Contents
3
1. OPERATING RANGE
5
2. SPECIFICATIONS
6
Outdoor Unit AER518SCL3
8
Indoor Unit AWR522CL
9
Outdoor Unit AER522SCL3
9
Outdoor Unit AER518SC3
10
Indoor Unit FCR522CL
11
Outdoor Unit AER522SC3
11
Outdoor Unit AER518SCL3
12
Indoor Unit FCR518CL
12
Indoor Unit FCR522CL
13
Outdoor Unit AER522SCL3
13
2-2-1. Indoor Unit
14
Indoor Unit AWR522CL
15
2-2-2. Outdoor Unit
18
Indoor Unit AWR518CL
20
AWR522CL
20
Indoor Unit FCR518CL
21
FCR522CL
21
Outdoor Unit AER518SC3
22
Outdoor Unit AER518SCL3
23
3. DIMENSIONAL DATA
26
Dimensions : mm
27
Air discharge
28
Air intake
28
Unit : mm
28
AER518SCL3
28
AER522SCL3
29
4. REFRIGERANT FLOW DIAGRAM
30
Indoor Unit Outdoor Unit
31
5. PERFORMANCE DATA
32
Floor mounted
33
Ceiling mounted
33
5-2. Coolling capacity
35
6. ELECTRICAL DATA
41
7. INSTALLATION INSTRUCTIONS
49
About 40 cm
50
Position
51
8. FUNCTION
53
8-3. Freeze Prevention
54
(FOR AER522SCL3)
56
9. REFRIGERANT R407C :
57
9-7-1.When tubes are extended
63
9-8-1 Use of existing units
63
9-8-2 Use of existing tubing
63
10. TROUBLESHOOTING
64
A. Power is not supplied
66
B. Check remote control unit
66
F. Check magnetic contactor
69
10-4-1. Poor cooling
73
10-4-2. Excessive cooling
73
Temperature
74
Thermistor Structure
74
Resistance
75
For Floor Installation
77
12-2. Removing Side Panels
78
12-3. Access and Removal of
78
Electrical Component Box
78
12-4. Removing Flap Motor
79
12-5. Removing Evaporator
79
(=Indoor Heat Exchange Coil)
79
Printed in italy
82
Komentarze do niniejszej Instrukcji
Brak uwag
Publish
Powiązane produkty i podręczniki dla Klimatyzatory typu split Argoclima AER522SCL3
Klimatyzatory typu split Argoclima AER522SCL3 Instrukcja Użytkownika
(34 strony)
Klimatyzatory typu split Argoclima AE522SC3 Instrukcja Użytkownika
(31 strony)
Drukuj dokument
Drukuj stronę 20
Komentarze do niniejszej Instrukcji